ASR 1002-HX= Specification
|
Physical specifications
|
Height: 3.5 in. (88.9 mm)
Width: 17.3 in. (439.4 mm)
Depth: 19.25 in. (489.0 mm)
Weight:
● 34 lb (15.45 kg) (with dual AC power supplies)
● 34 lb (15.45 kg) (with dual DC power supplies)
|
Default memory
|
16-GB DRAM shared across route processor, ESP, and MIP
|
Number of SIPs or Ethernet line cards supported
|
Integrated in chassis
|
Shared port adapters
|
N/A
|
Ethernet port adapters
|
1 EPA slot
|
Cisco ASR 1000 Series ESP
|
Integrated in chassis
|
Route processor
|
Integrated in the chassis: Cisco ASR 1002-HX Series Route Processor
|
Redundancy
|
Software: Yes
|
Built-in Gigabit Ethernet ports
|
Yes: 8 Gigabit Ethernet SFP ports
|
Built-in 10 Gigabit Ethernet port
|
Yes: Eight 10 Gigabit Ethernet Small Form-Factor Plus Pluggable (SFP+) ports
Note:Built-in 10-GB ports cannot be reduced to 1-GB speed.
|
Network interface module
|
Yes
|
ESP support
|
Cisco ASR 1000 Series 100-Gbps ESP (ASR1000-ESP100) equivalent
|
ESP bandwidth
|
100 Gbps
|
ESP memory
|
Share the same control memory on route processor
|
SIPs and Ethernet line cards
|
Integrated in chassis: not upgradable
|
Embedded hardware-based encryption
|
Yes: Up to 25-Gbps crypto support throughput
|
Minimum Cisco IOS XE Software release
|
Cisco IOS XE Software Release 16.2.1S
|
Rack-mounting
|
Yes: 19-inch
|
Wall-mounting
|
No
|
External USB flash memory
|
1-GB USB flash-memory support
|
Redundant power supply
|
Yes: Dual power supplies by default; option of either AC or DC power supply
Note: A mix of one AC and one DC power supply is not supported.
|
Power input
|
Worldwide ranging AC input range (85 to 264 VAC)
Worldwide ranging DC
(-40 to -72; -48V nominal)
|
Power consumption
|
● Maximum (DC): 500W
● Maximum (AC): 500W
|
Airflow
|
Front-to-back
|
Operating temperature (nominal)
|
32 to 104°F
(0 to 40°C)
|
Operating temperature (short-term)
|
32 to 122°F
(0 to 50°C)
|
Operating humidity (nominal) (relative humidity)
|
10 to 85%
|
Operating humidity (short-term)
|
5 to 90%
|
Storage temperature
|
-40 to 150°F
(-40 to 70°C)
|
Storage humidity (relative humidity)
|
5 to 95%
|
Operating altitude
|
-500 to 10,000 feet
(152 to 3048 meters)
|
Network Equipment Building Standards (NEBS)
|
GR-1089 and GR-63
|
EMC standards
|
Emissions
● FCC 47CFR15 Class A
● AS/NZS CISPR 22
● CISPR 22 Class A
● EN55022 Class A
● ICES-003 Class A
● VCCI Class A
● CNS-13438 Class A
● EN61000-3-2
● EN61000-3-3
Immunity
● IEC/EN61000-4-2 Electrostatic Discharge Immunity
● IEC/EN61000-4-3 Radiated Immunity
● IEC/EN61000-4-4 EFT-B Immunity
● IEC/EN61000-4-5 Surge
● IEC/EN61000-4-6 Immunity to Conducted Disturbances
● IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity
● IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations
ETSI/EN
● EN55022/CISPR 22 Information Technology Equipment (Emissions)
● EN55024/CISPR 24 Information Technology Equipment (Immunity)
● EN300 386 Telecommunications Network Equipment
● EN50082-1/EN61000-6-1 Generic Immunity Standard
|
Safety Standard
|
UL60950-1
CSA C22.2 No. 60950-1-03
EN 60950-1
IEC 60950-1
AS/NZS 60950.1
|